Affinity and kinetic parameters (with background subtracted)

mAb ID ka, 1/Ms kd, 1/s KA, 1/M KD, M RMax, RU
5A8 3.6 × 105 2.0 × 10−4 2.1 × 109 1.5 × 10−9 172
3C7 1.7 × 105 7.6 × 10−4 5.2 × 108 5.6 × 10−9 133
3D6 1.8 × 106 1.2 × 10−4 1.5 × 1010 8.0 × 10−11 294
5D12 5.4 × 105 3.2 × 10−4 2.0 × 109 7.0 × 10−10 272
3G9 9.0 × 105 1.9 × 10−4 4.7 × 109 2.4 × 10−10 268

For each antibody, the figures shown are the mean of 2 separate series of experiments, using separately prepared sensor chips in each case, where: ka indicates kinetics of association; kd, kinetics of dissociation; KD, dissociation rate constant (measure of affinity); KA, association rate constant; and RMax, maximum SPR response signal.