Skip to main content
. 2010 Feb 17;30(7):2741–2754. doi: 10.1523/JNEUROSCI.5390-09.2010

Table 2.

Maximum interval likelihood fitting of the sequence of open and closed durations

Rates Experimental
Scheme I
Glycine DCS Glycine DCS
k1+ 470 ± 85 420 ± 80
k1− 890 ± 265 1270 ± 340
k2+ 860 ± 160 1395 ± 215*
k2− 15,630 ± 1700 17,510 ± 2135
k3+ 3735 ± 590 4795 ± 815
k3− 2630 ± 270 2150 ± 210*
k4+ 60 ± 15 75 ± 35
k4− 1310 ± 225 1070 ± 130
d1+ 0.8 ± 0.3 1.2 ± 0.4
d1− 3.8 ± 1.0 4.2 ± 1.0
d2+ 17 ± 5 25 ± 8
d2− 33 ± 8 38 ± 7
LL/event 4.91 ± 0.03 4.86 ± 0.05
Po 0.019 0.028 0.018 0.029
MOT 0.46 0.57 0.46 0.61

Idealized current single-channel records were fitted to Scheme 1 as described in Figure 8. All rates have units of s−1. Data are mean ± SEM from six patches, each containing one active channel with a total of 11,275 and 16,662 open periods and 11,272 and 16,657 closed periods for glycine and DCS, respectively. The rates were compared by paired t test. *p < 0.05. MOT, mean open time.