Table 2.

Average Measurements (N = 10) and Measurement Differences of Cardiac Function for 2D FT vs. 3D PR

LVEF (%) LVEDV (mL) LVESV (mL) LVEDM (g)
3D PR SSFP 62 ± 3 172 ± 40 64 ± 13 93 ± 33
2D FT SSFP 63 ± 4 166 ± 36 61 ± 14 92 ± 28
P-value  0.623 0.102 0.172         0.775
Mean bias ± 2 SD  0.6% ± 7.7% 5.9 mL ± 20 mL −2.8 mL ± 12 mL −0.61g ± 13 g

LVEF = left ventricular ejection fraction, LVEDV = left ventricular end diastolic volume, LVESV = left ventricular end systolic volume, LVEDM = left ventricular end diastolic mass, SD = standard deviation.